产品 / 手动工具 / 电力检测&数字万用表
品牌
2AC FLUKE VOLTALERT DETECTOR 200-1000V

2AC FLUKE VOLTALERT DETECTOR 200-1000V

编号:FLU5161290A
●产品描述:
Fluke VoltAlert™ Voltage Detector

2AC
2AC is the latest addition to the VoltAlert™ ac non-contact voltage tester family from Fluke and is designed to be pocket-sized and easy to use. The 2AC tests for energised circuits and defective grounds, whether it’s for an electrician on the factory floor or the do-it-yourselfer around the house. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present.

Specifications:
Voltage detection from 200 to 1000V AC, suitable for a wide range of residential, commercial and industrial needs. Always on, using special low power circuitry to sustain battery life and ensure your 2AC is always ready. Innovative ‘battery check’ button function ensures battery is in good condition. Category IV – 1000V over-voltage rated product for best in class user protection. Integrated clip design, optimised for pocket storage. Powered by 2x AAA batteries (included). Fluke ruggedness and reliability. Two-year warranty.



T5-600 ELECTRICAL TESTERVOLT, CONTINUITY, CURRENT

T5-600 ELECTRICAL TESTERVOLT, CONTINUITY, CURRENT

编号:FLU5167050Q
●产品描述:
FLUKE T5-600 Electrical Tester

Checks voltage, continuity and current. Integral test lead storage. OpenJaw current allows checking of current up to 100 amps without breaking the circuit. Measures Volts ac/dc and resistance, continuity beeper, data hold button, detachable Slim-Reach probe tips, two years manufacturers warranty. All inputs are protected to EN61010-1 Cat III 600V.



179 FLUKE MULTIMETER

179 FLUKE MULTIMETER

编号:FLU5161179K
●产品描述:
179 True RMS Voltage and Current Measurements Multimeter

0.09% basic accuracy, 6000 count resolution. Digital display with analogue bargraph and backlight. Manual and automatic ranging. Display hold and auto hold. Frequency and capacitance measurements. Resistance, continuity and diode measurements. Temperature measurements.
Min-max-average recording. Smoothing mode allows filtering of rapidly changing inputs. Easy battery exchange without opening the case. Closed case calibration through front panel. Ergonomic case with integrated protective holster. EN61010-1 Cat III 1000V/Cat IV 600V. Measures twice as fast as other multimeters
Accessories include:
80BK temperature probe. Installed 9V battery. Test leads. Users manual.



1-AC-II VOLT STICK ACV DETECTOR 200-1000V

1-AC-II VOLT STICK ACV DETECTOR 200-1000V

编号:FLU5161002B
●产品描述:
VoltAlert&153; Volt Detector 1AC-II

When the tip glows red and the unit beeps, you know there's voltage present. Quickly tests for energised circuits in the workplace or at home. Voltage sensing ranges: nominally, 200V AC to 1000V AC
Agency approvals: c CSA us, CE, TUV, C-Tick.
Safety rating: 1000V, Cat IV.



373 - 600A TRMS AC CLAMPMETER

373 - 600A TRMS AC CLAMPMETER

编号:FLU5161373E
●产品描述:
Fluke Multimeters

These new clampmeters from Fluke, provide the highest level of safety and performance in a rugged ergonomic package. They are True RMS measuring to provide accurate measurements on today?s electronic systems.

Most models measure both AC & DC current and voltage, and have additional features to aid in troubleshooting everyday problems.

Designed to operate in harsh environments, some models have an integrated low pass filter and signal processing for stable readings in electrically noisy areas.

Models that feature Fluke's proprietary inrush measurement technology, filter out noise & capture motor starting current exactly as the circuit protection sees it.

373 True-rms AC Clamp Meter

The new Fluke 373 clamp meters offers improved performance perfect for many AC only current measurement situations. With true-RMS AC voltage and current measurements, the Fluke 373 reads up to 600A AC and 600V AC or DC.

Fluke model number: 373
Application: Industrial/Residential/Commercial
Cable size jaw (& cable size iFlex): 32 mm
i-flex flexible current probe included: n/a
True RMS: YES
AC Current (clamp) to: 600A
AC Current (i-flex) to: n/a
DC Current (clamp) to: n/a
AC Voltage to: 600V
DC Voltage to: 600V
Resistance & Continuity: YES
Frequency to 400Hz: n/a
Temperature measurement -10°C to + 400°C: n/a
Motor Start-up (inrush current) capture: n/a
Detachable jaw clamp & torch: n/a
Low pass filter for noisy environments: n/a
Removable display operates up to 10 metres: n/a
mV range compatible with other accs: n/a
Min/Max logging: n/a
Display backlight: YES
Display Hold: YES
Warranty (years): 3
Safety rating: CAT III 600 V, Cat IV 300 V

Note : Cat IV is a higher safety rating
114 AUTO RANGING MULTIMETER ELECTRICAL

114 AUTO RANGING MULTIMETER ELECTRICAL

编号:FLU5161124A
●产品描述:
Electrical Multimeter

114
Used for troubleshooting on `go/no-go` testing. It includes a feature to prevent false readings caused by ghost voltage. Voltage max: 600V DC. Continuity: 600. Safety rating: Cat III 600V.



TL80A-1 FLUKE ELECTRONICTEST LEAD SET

TL80A-1 FLUKE ELECTRONICTEST LEAD SET

编号:FLU5167580H
●产品描述:
Fluke Electronic Test Lead Set

TL80A-1
Economical accessories for making measurements in low energy, electronic applications. One pair (red, black) each 1 meter long WearGuard™ test lead set, TL71-1. Exposes contrasting colour when leads are damaged and need replacing. Compatible with all instruments that accept standard 4mm, shrouded banana connectors. EN/IEC 61010-031:2002 +A1:2008. Includes: alligator clips, 5A max. insulated extended probe tips, 3A max. C75 soft carrying case. One year warranty.



1503 INSULATION TESTER

1503 INSULATION TESTER

编号:FLU5161150M
●产品描述:
Fluke 1507/1503 Insulation Resistance Testers

The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.
Additional features, like the remote probe on these tools save both time and money when performing tests
Features;
Insulation test range:
1507: 0.01 MΩ to 10 GΩ
1503: 0.1 MΩ to 2000 MΩ
Insulation test voltages:
1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000 V
Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
Make repetitive tests simple and easy with the 1507?s Compare (Pass/Fail) function (only available on the 1507)
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 kΩ
Save battery power with auto power off
Read measurements easily with large, backlit display
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty



Specification;
AC/DC Voltage Measurement
Accuracy;
Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz (% of Rdg + Digits) (2 % + 3)

Input impedance; 3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced); > 60 dB at dc, 50 or 60 Hz

Overload Protection; 600 V rms or dc

Earth bond resistance measurement;
Range/Resolution; 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ

Accuracy; (1.5 % + 3)

Overload Protection; 2 V rms or dc

Open Circuit Test Voltage; > 4.0 V, < 8 V

Short circuit current; > 200.0 mA

Insulation specifications;
Measurement Range; 1507: 0.01 MΩ to 10 GΩ
1503: 0.01 MΩ to 2000 MΩ

Test voltage; 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000V

Test Voltage Accuracy; + 20 %, - 0 %

Short circuit current; 1 mA nominal

Auto Discharge; Discharge time < 0.5 second for C = 1 F or less

Live circuit indicator; Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum Capacitive Load; Operable with up to 1 F load

Measure Accuracy:
50 V: (3 % + 5)
100 V: (3 % + 5)
250 V: (1.5 % + 5)
500 V: (1.5 % + 5)
1000 V: (1.5 % + 5) to 2000 MΩ, (10 % + 3) above 2000 MΩ

General Specifications;
Maximum voltage applied to any terminal:600 V ac rms or dc

Storage Temperature; -40 C to 60 C (-40 F to 140 F)

Operating Temperature; -20 C to 55 C (-4 F to 131 F)

Temperature Coefficient; 0.05 x (specified accuracy) per C for temperatures < 18 C or > 28 C (< 64 F or > 82 F)

Relative Humidity;
0 % to 95 % @ 10 C to 30 C (50 F to 86 F)
0 % to 75 % @ 30 C to 40 C (86 F to 104 F)
0 % to 40 % @ 40 C to 55 C (104 F to 131 F)

Vibration; Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock; 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

Safety; Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

Batteries; Four AA batteries (NEDA 15A or IEC LR6)

Battery Life;
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

Size; 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)

Weight; 550 g (1.2 lb)

IP Rating; IP40

Altitude;
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m

Over-range capability: 110 % of range

Included accessories:TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
1507 INSULATION TESTER

1507 INSULATION TESTER

编号:FLU5161151N
●产品描述:
Fluke 1507/1503 Insulation Resistance Testers

The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.
Additional features, like the remote probe on these tools save both time and money when performing tests
Features;
Insulation test range:
1507: 0.01 MΩ to 10 GΩ
1503: 0.1 MΩ to 2000 MΩ
Insulation test voltages:
1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000 V
Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
Make repetitive tests simple and easy with the 1507?s Compare (Pass/Fail) function (only available on the 1507)
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 kΩ
Save battery power with auto power off
Read measurements easily with large, backlit display
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty



Specification;
AC/DC Voltage Measurement
Accuracy;
Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz (% of Rdg + Digits) (2 % + 3)

Input impedance; 3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced); > 60 dB at dc, 50 or 60 Hz

Overload Protection; 600 V rms or dc

Earth bond resistance measurement;
Range/Resolution; 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ

Accuracy; (1.5 % + 3)

Overload Protection; 2 V rms or dc

Open Circuit Test Voltage; > 4.0 V, < 8 V

Short circuit current; > 200.0 mA

Insulation specifications;
Measurement Range; 1507: 0.01 MΩ to 10 GΩ
1503: 0.01 MΩ to 2000 MΩ

Test voltage; 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000V

Test Voltage Accuracy; + 20 %, - 0 %

Short circuit current; 1 mA nominal

Auto Discharge; Discharge time < 0.5 second for C = 1 F or less

Live circuit indicator; Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum Capacitive Load; Operable with up to 1 F load

Measure Accuracy:
50 V: (3 % + 5)
100 V: (3 % + 5)
250 V: (1.5 % + 5)
500 V: (1.5 % + 5)
1000 V: (1.5 % + 5) to 2000 MΩ, (10 % + 3) above 2000 MΩ

General Specifications;
Maximum voltage applied to any terminal:600 V ac rms or dc

Storage Temperature; -40 C to 60 C (-40 F to 140 F)

Operating Temperature; -20 C to 55 C (-4 F to 131 F)

Temperature Coefficient; 0.05 x (specified accuracy) per C for temperatures < 18 C or > 28 C (< 64 F or > 82 F)

Relative Humidity;
0 % to 95 % @ 10 C to 30 C (50 F to 86 F)
0 % to 75 % @ 30 C to 40 C (86 F to 104 F)
0 % to 40 % @ 40 C to 55 C (104 F to 131 F)

Vibration; Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock; 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

Safety; Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

Batteries; Four AA batteries (NEDA 15A or IEC LR6)

Battery Life;
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

Size; 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)

Weight; 550 g (1.2 lb)

IP Rating; IP40

Altitude;
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m

Over-range capability: 110 % of range

Included accessories:TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
C25 SOFT CASE FOR MULTIMETER

C25 SOFT CASE FOR MULTIMETER

编号:FLU5162025B
●产品描述:
C25

Zippered carrying case with padding and inside pocket.One year warranty
Compatibility
• 114/115/116/117
• 175/177/179
• 1503/1507/1577/1587
• 9040/9062
• 922
• 971
• 51/52/53/54 II