产品 / 手动工具 / 电力检测&数字万用表
品牌
T5-1000 ELECTRICAL TESTER

T5-1000 ELECTRICAL TESTER

编号:FLU5167070R
●产品描述:
T5-1000

Tester for voltage, continuity and current. The fixed fork allows the testing of currents without breaking the circuit. The test leads can be stored on the back side, saving space



Easy and accurate OpenJaw™ current measurement
Continuity beeper
Compact design with neat probe storage
Auto off mode to conserve battery life

AC Voltage: 100V
DC voltage: 1000V
AC./DC current 100A
Resistance: 1000W
Calibration Frequency:45 to 66 Hz
Digital Display Count 1000
Safety Category: 1000V CAT III
Weight: 300g
Size: (H x W x D)230 x 51 x 30.5mm
77-IV MULTIMETER

77-IV MULTIMETER

编号:FLU5160770D
●产品描述:
77-IV

The 77-IV has the features needed to repair most electrical and electronic problems. A large display and backlight assists work in dim areas. Minium/Maxium to record signal fluctuations. Ergonomic overmolded housing with integrated probe holders. Auto and manual ranging and it meets Measurement Category 1000

It measures:
Wide 1000 V measurement range
Average responding AC measurements
0.3% accuracy
10 Amps continuous (20A for 30 seconds)
Frequency and capacitance
Resistance and continuity

Measurement Category IV safety rating



TL220-1 SUREGRIP INDUSTRIAL TEST LEAD SET

TL220-1 SUREGRIP INDUSTRIAL TEST LEAD SET

编号:FLU5167620P
●产品描述:
Fluke SureGrip™ Industrial Test Lead Kit

TL220-1
Handy all-in-one kit that includes:
AC220 SureGrip™ alligator clip set,
TP238 SureGrip™ insulated test probe set, TL222 SureGrip™ silicone test lead set. One year warranty.



T5-600 ELECTRICAL TESTERVOLT, CONTINUITY, CURRENT

T5-600 ELECTRICAL TESTERVOLT, CONTINUITY, CURRENT

编号:FLU5167050Q
●产品描述:
FLUKE T5-600 Electrical Tester

Checks voltage, continuity and current. Integral test lead storage. OpenJaw current allows checking of current up to 100 amps without breaking the circuit. Measures Volts ac/dc and resistance, continuity beeper, data hold button, detachable Slim-Reach probe tips, two years manufacturers warranty. All inputs are protected to EN61010-1 Cat III 600V.



115 AUTO RANGING MULTIMETER

115 AUTO RANGING MULTIMETER

编号:FLU5161125B
●产品描述:
Digital Multimeter

115
Used for a wide variety of electrical and electronic testing application. This true-rms meter provides easy one handed operation in a compact package. Voltage max: 600V AC/DC. Current max: 20A DC. Capacitance max: 1000uF. Frequency max: 50kHz. Continuity: 600. Diode: 2V. Safety rating: Cat III 600V.



C25 SOFT CASE FOR MULTIMETER

C25 SOFT CASE FOR MULTIMETER

编号:FLU5162025B
●产品描述:
C25

Zippered carrying case with padding and inside pocket.One year warranty
Compatibility
• 114/115/116/117
• 175/177/179
• 1503/1507/1577/1587
• 9040/9062
• 922
• 971
• 51/52/53/54 II



1503 INSULATION TESTER

1503 INSULATION TESTER

编号:FLU5161150M
●产品描述:
Fluke 1507/1503 Insulation Resistance Testers

The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.
Additional features, like the remote probe on these tools save both time and money when performing tests
Features;
Insulation test range:
1507: 0.01 MΩ to 10 GΩ
1503: 0.1 MΩ to 2000 MΩ
Insulation test voltages:
1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000 V
Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
Make repetitive tests simple and easy with the 1507?s Compare (Pass/Fail) function (only available on the 1507)
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 kΩ
Save battery power with auto power off
Read measurements easily with large, backlit display
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty



Specification;
AC/DC Voltage Measurement
Accuracy;
Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz (% of Rdg + Digits) (2 % + 3)

Input impedance; 3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced); > 60 dB at dc, 50 or 60 Hz

Overload Protection; 600 V rms or dc

Earth bond resistance measurement;
Range/Resolution; 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ

Accuracy; (1.5 % + 3)

Overload Protection; 2 V rms or dc

Open Circuit Test Voltage; > 4.0 V, < 8 V

Short circuit current; > 200.0 mA

Insulation specifications;
Measurement Range; 1507: 0.01 MΩ to 10 GΩ
1503: 0.01 MΩ to 2000 MΩ

Test voltage; 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000V

Test Voltage Accuracy; + 20 %, - 0 %

Short circuit current; 1 mA nominal

Auto Discharge; Discharge time < 0.5 second for C = 1 F or less

Live circuit indicator; Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum Capacitive Load; Operable with up to 1 F load

Measure Accuracy:
50 V: (3 % + 5)
100 V: (3 % + 5)
250 V: (1.5 % + 5)
500 V: (1.5 % + 5)
1000 V: (1.5 % + 5) to 2000 MΩ, (10 % + 3) above 2000 MΩ

General Specifications;
Maximum voltage applied to any terminal:600 V ac rms or dc

Storage Temperature; -40 C to 60 C (-40 F to 140 F)

Operating Temperature; -20 C to 55 C (-4 F to 131 F)

Temperature Coefficient; 0.05 x (specified accuracy) per C for temperatures < 18 C or > 28 C (< 64 F or > 82 F)

Relative Humidity;
0 % to 95 % @ 10 C to 30 C (50 F to 86 F)
0 % to 75 % @ 30 C to 40 C (86 F to 104 F)
0 % to 40 % @ 40 C to 55 C (104 F to 131 F)

Vibration; Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock; 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

Safety; Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

Batteries; Four AA batteries (NEDA 15A or IEC LR6)

Battery Life;
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

Size; 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)

Weight; 550 g (1.2 lb)

IP Rating; IP40

Altitude;
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m

Over-range capability: 110 % of range

Included accessories:TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
116 FLUKE TRUE RMS MULTIMETER

116 FLUKE TRUE RMS MULTIMETER

编号:FLU5161126C
●产品描述:
True RMS Multimeter

Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. Specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.
Includes holster, 4mm silicone test lead set 9V battery and user manual.



175 FLUKE TRUE RMS DMM C/W LIFETIME WARRANTY

175 FLUKE TRUE RMS DMM C/W LIFETIME WARRANTY

编号:FLU5161175R
●产品描述:
Fluke 175 True RMS Multimeter

0.15% basic accuracy
6000 count resolution.
Manual and automatic ranging.
Frequency and capacitance measurements.
Resistance, continuity and diode measurements.
Min-max-average recording
EN61010-1 Cat III 1000V/Cat IV 600V



374 - 600A TRMS AC/DC CLAMP METER

374 - 600A TRMS AC/DC CLAMP METER

编号:FLU5161374F
●产品描述:
Fluke Multimeters

These new clampmeters from Fluke, provide the highest level of safety and performance in a rugged ergonomic package. They are True RMS measuring to provide accurate measurements on today?s electronic systems.

Most models measure both AC & DC current and voltage, and have additional features to aid in troubleshooting everyday problems.

Designed to operate in harsh environments, some models have an integrated low pass filter and signal processing for stable readings in electrically noisy areas.

Models that feature Fluke's proprietary inrush measurement technology, filter out noise & capture motor starting current exactly as the circuit protection sees it.

374 True-rms AC Clamp Meter

The new Fluke 374 clamp meter offers improved performance perfect for many current measurement situations. With true-RMS AC voltage and current measurements, the Fluke 374 can read up to 600V and 600A in both AC and DC modes.


Fluke model number: 374
Application: Industrial/Residential/Commercial
Cable size jaw (& cable size iFlex): 34 mm (100mm)
i-flex flexible current probe included: Available separately.
True RMS: YES
AC Current (clamp) to: 600A
AC Current (i-flex) to: 2500A
DC Current (clamp) to: 600A
AC Voltage to: 600V
DC Voltage to: 600V
Resistance & Continuity: YES
Frequency to 400Hz: n/a
Temperature measurement -10°C to + 400°C: n/a
Motor Start-up (inrush current) capture: YES
Detachable 'jaw clamp' & torch: n/a
Low pass filter for noisy environments: n/a
Removable display operates up to 10 metres: n/a
mV range compatible with other accs: n/a
Min/Max logging: YES
Display backlight: YES
Display Hold: YES
Warranty (years): 3
Safety rating: CAT III 1000V, Cat IV 600 V

Note : Cat IV is a higher safety rating