●产品描述:
Volt Stick

An instant tester for safely checking the presence of an AC voltage, without making any disconnections in cables, wall sockets, fuses, circuit breakers, junction boxes, etc. No current flow is needed for correct operation. The red indicator in the tip will illuminate on detection of AC voltage simply by applying the tip close to any connection point, or moving it along any insulated cable. The PRO12 features a unique ?shielded? forktip for highly selective and accurate testing for presence of AC voltage in specific cables or wires. Ideal for professional, close proximity testing and installation work. Cables and connections can easily be checked in low voltage equipment too. Extremely safe when measuring in junction boxes, with the supplied field strength amplifier, anti-tamper, earthed outlets can be checked. Powerful red light in the tip to indicate voltage. Fully insulated for safe use.

Volt Stick PRO12

117 AUTO RANGING MULTIMETER C/W VOLT-ALERT

117 AUTO RANGING MULTIMETER C/W VOLT-ALERT

编号:FLU5161127D
●产品描述:
Electrician's Multimeter

117
Ideal for demanding settings such as commercial buildings, hospitals and schools. Includes integrated non-contact voltage detection. Voltage max: 600V DC. Current max: 20A AC. Capacitance max: 1000uF. Frequency max: 50kHz. Continuity: 600. Diode: 2V. Safety rating: Cat III 600V. Warranty: 1 year.



FTL660 FLUKE FUSED TEST LEADS

FTL660 FLUKE FUSED TEST LEADS

编号:FLU5163660D
●产品描述:
Fluke Test Leads

Set contents: Industrial test probes, rectangle test leads and heavy duty alligator clips. Fused test leads. Can be used with most multimeters.



77-IV MULTIMETER

77-IV MULTIMETER

编号:FLU5160770D
●产品描述:
77-IV

The 77-IV has the features needed to repair most electrical and electronic problems. A large display and backlight assists work in dim areas. Minium/Maxium to record signal fluctuations. Ergonomic overmolded housing with integrated probe holders. Auto and manual ranging and it meets Measurement Category 1000

It measures:
Wide 1000 V measurement range
Average responding AC measurements
0.3% accuracy
10 Amps continuous (20A for 30 seconds)
Frequency and capacitance
Resistance and continuity

Measurement Category IV safety rating



175 FLUKE TRUE RMS DMM C/W LIFETIME WARRANTY

175 FLUKE TRUE RMS DMM C/W LIFETIME WARRANTY

编号:FLU5161175R
●产品描述:
Fluke 175 True RMS Multimeter

0.15% basic accuracy
6000 count resolution.
Manual and automatic ranging.
Frequency and capacitance measurements.
Resistance, continuity and diode measurements.
Min-max-average recording
EN61010-1 Cat III 1000V/Cat IV 600V



1-AC-II VOLT STICK ACV DETECTOR 200-1000V

1-AC-II VOLT STICK ACV DETECTOR 200-1000V

编号:FLU5161002B
●产品描述:
VoltAlert&153; Volt Detector 1AC-II

When the tip glows red and the unit beeps, you know there's voltage present. Quickly tests for energised circuits in the workplace or at home. Voltage sensing ranges: nominally, 200V AC to 1000V AC
Agency approvals: c CSA us, CE, TUV, C-Tick.
Safety rating: 1000V, Cat IV.



VOLT STICK SOUND 230V ACGREEN

VOLT STICK SOUND 230V ACGREEN

编号:CAN5163548C
●产品描述:
Volt Stick SOUND

The original and still the best, is an instant tester for safely checking the presence of an AC voltage, without making any disconnections in cables, wall sockets, fuses, circuit breakers, junction boxes, etc. No current flow is needed for correct operation. The red indicator in the tip will illuminate on detection of AC voltage simply by applying the tip close to any connection point, or moving it along any insulated cable.
The brand new Volt Stick SOUND now features a detection buzzer for even greater clarification. Also ideal for detection round corners', in bright daylight and in awkward out of sight areas. High visibility green tube for ease of identification if dropped or hidden in the toolbox.
Features:
Added Bleeper' feature
Locates breaks in cables
Detects blown fuses inside plugs or fuse holders
Distinguishes between live and neutral wires in both single and three-phase supplies
Identifies voltage-carrying cables in junction boxes
Identifies faulty in-line switches
Locates defective in-series light bulbs



Specifications
Model: Volt Stick SOUND:
Voltage range: 220 ~ 230 Volts AC
Sensitivity: Functions @ 4mm distance from 2.5mm
conductor carrying 220V AC
Response Time: Immediate
Intrinsically Safe: No
Power Requirements: 2 x AAA (LR03) batteries (inc)
RH: 80% @ 30C, 50% @ 40C
Operating Temp: -10 ~ +50C
Overvoltage: CAT III 1000V AC
Dimensions: 145(L) x 18(W) x 20(H) mm
Weight: 40g (inc.batteries)
All models are fully approved to IEC 61010-1, CAT111 1000V AC and CE.
1503 INSULATION TESTER

1503 INSULATION TESTER

编号:FLU5161150M
●产品描述:
Fluke 1507/1503 Insulation Resistance Testers

The Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.
Additional features, like the remote probe on these tools save both time and money when performing tests
Features;
Insulation test range:
1507: 0.01 MΩ to 10 GΩ
1503: 0.1 MΩ to 2000 MΩ
Insulation test voltages:
1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000 V
Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
Make repetitive tests simple and easy with the 1507?s Compare (Pass/Fail) function (only available on the 1507)
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 kΩ
Save battery power with auto power off
Read measurements easily with large, backlit display
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty



Specification;
AC/DC Voltage Measurement
Accuracy;
Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz (% of Rdg + Digits) (2 % + 3)

Input impedance; 3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced); > 60 dB at dc, 50 or 60 Hz

Overload Protection; 600 V rms or dc

Earth bond resistance measurement;
Range/Resolution; 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ

Accuracy; (1.5 % + 3)

Overload Protection; 2 V rms or dc

Open Circuit Test Voltage; > 4.0 V, < 8 V

Short circuit current; > 200.0 mA

Insulation specifications;
Measurement Range; 1507: 0.01 MΩ to 10 GΩ
1503: 0.01 MΩ to 2000 MΩ

Test voltage; 1507: 50 V, 100 V, 250 V, 500 V, 1000 V
1503: 500 V, 1000V

Test Voltage Accuracy; + 20 %, - 0 %

Short circuit current; 1 mA nominal

Auto Discharge; Discharge time < 0.5 second for C = 1 F or less

Live circuit indicator; Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum Capacitive Load; Operable with up to 1 F load

Measure Accuracy:
50 V: (3 % + 5)
100 V: (3 % + 5)
250 V: (1.5 % + 5)
500 V: (1.5 % + 5)
1000 V: (1.5 % + 5) to 2000 MΩ, (10 % + 3) above 2000 MΩ

General Specifications;
Maximum voltage applied to any terminal:600 V ac rms or dc

Storage Temperature; -40 C to 60 C (-40 F to 140 F)

Operating Temperature; -20 C to 55 C (-4 F to 131 F)

Temperature Coefficient; 0.05 x (specified accuracy) per C for temperatures < 18 C or > 28 C (< 64 F or > 82 F)

Relative Humidity;
0 % to 95 % @ 10 C to 30 C (50 F to 86 F)
0 % to 75 % @ 30 C to 40 C (86 F to 104 F)
0 % to 40 % @ 40 C to 55 C (104 F to 131 F)

Vibration; Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock; 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

Safety; Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

Batteries; Four AA batteries (NEDA 15A or IEC LR6)

Battery Life;
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

Size; 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)

Weight; 550 g (1.2 lb)

IP Rating; IP40

Altitude;
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m

Over-range capability: 110 % of range

Included accessories:TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
0-77-255 INTELLISENSOR PRO STUD LOCATOR

0-77-255 INTELLISENSOR PRO STUD LOCATOR

编号:STX5855550X
●产品描述:
IntelliSensor&153; Pro Stud Sensor

Locates the edge of studs or joists through drywall and other common wall materials at a maximum depth of 1/2&34; and 11/2&34;. Automatic calibration switch. Multi-mode LED panel for depth indication. Buzzer indicates stud and joist edges. High impact ABS housing for strength and durability. Large, patented LCD screen for visual detection warning. Continuous live wire detection. Requires a 9V battery (not included). Automatic shut-off for longer battery life.



REPLACEMENT PROBE FOR EDI5162900K

REPLACEMENT PROBE FOR EDI5162900K

编号:EDI5169030K
●产品描述:
Edison™ Multimeters

Suitable for the Edison™ DM383 Order Code: EDI-516-2900K.

Replacement Multimeter Probes